Hors Stock Appeler pour vérifier E.Q.'s & De-essers Tube TechME 1B TUBEBF8D0D 2 975 € Impedance Input: 600 Ohm Output < 60 Ohm Frequency response @ -3dB 5 Hz to 40 kHz Distortion THD+N @ 40Hz 0 dBU 0,15 % +10 dBU 0,15 % Max. output: +26 dBU < 1 % Max. input: +21 dBU < 1 % NoiseRg=200 Ohm 22 Hz-22 kHz < -80 dBU CCIR-468-4 < -70 dBU CMMR@ 10 kHz < - 60 dB... Voir
Hors Stock Appeler pour vérifier Compresseurs gates limiteurs Tube TechLCA 2B TUBE385684 4 500 € Impedance Input: 5K ohm Output: < 60 ohm Frequency response @ -3 dB: 5 Hz to 40 kHz Distortion THD+N @ 40 Hz < 0,15 % < 0,15 % Max. output: +26 dBU - < 1 % THD Max input PAD: +21 dBU - < 1 % THD Noise Rg=200 ohm Gain: 0 dB - +10 dB 22Hz-22kHz: < -85 dBU - < -80 dBU CCIR-468-4: <... Voir
Hors Stock Appeler pour vérifier E.Q.'s & De-essers Tube TechHLT2A TUBE6C4A59 3 445 € Input impedance: >10 kΩ Output impedance: < 60Ω Frequency response (-3dB): 5 Hz - 55 kHz Distortion (THD+n @ 40 Hz):0 dBU: 10 dBU: Max output (1% THD+n): > Max input (1% THD+n): < 0,10 % < 0,10 %+26 dBU> +25 dBU Noise (Rg=200Ω):22Hz-22kHz: CCIR-468-4: < -85 dBU< -75 dBU CMRR (@ 10kHz):... Voir
Hors Stock Appeler pour vérifier Compresseurs gates limiteurs Tube TechCL 2A TUBE3630D9 4 115 € Impedance Input: 5K ohm Output: < 60 ohm Frequency response @ -3 dB: 5 Hz to 40 kHz Distortion THD+N @ 40 Hz 0 dBU - < 0,15 % +10 dBU - < 0,15 % Max. output: +26 dBU - < 1 % THD Max input PAD: +21 dBU - < 1 % THD Noise Rg=200 ohm Gain: 0 dB - +10 dB 22Hz-22kHz: < -80 dBU - < -80 dBU... Voir
Hors Stock Appeler pour vérifier Compresseurs gates limiteurs Tube TechCL 1B TUBE66F3E2 3 500 € Impedance Input: 600 Ohm Output < 60 Ohm Frequency response @ -3dB 5 Hz to 25 Hz Distortion THD+N @ 40Hz 0 dBU 0,15 % +10 dBU 0,15 % Max. output: +26 dBU - < 1 % Max. input: +21 dBU - < 1 % Noise Rg=200 Ohm Output Gain @ 0 dB - +30 dB 22 Hz-22 kHz < -85 dBU - < -75 dBU CCIR-468-4 < -75... Voir
Hors Stock Appeler pour vérifier Micros Condensateur à Grande Membrane JZ MicrophonesBH2 JZBHTH043K 655 € Transducer Type electrostaticOperating principle pressure gradientPolar Patterns CardioidDiaphragm’s active diameter 27 mmFrequency Response 20 Hz - 20 kHzSensitivity at 1 kHz 21 mV/PaOutput Impedance 50ΩRate Load Impedance >100ΩMaximum SPL 134.5 dB SPL (2.5kΩ, 0.5% THD)S/N Ratio 87.5 dB-ANoise Level 6.5 dB-ADynamic Range 128dBPower Requirement + 48V... Voir
Hors Stock Appeler pour vérifier Kits de Micros Se ElectronicsV Pack Venue SEEL5B15E7 800 € Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Grande Membrane Se ElectronicsX1 S SEEL9C3C24 160 € Capsule Type: Hand-Crafted 1" True CondenserPolar Pattern: CardioidFrequency range: 20 Hz - 20 kHzSensitivity: 30 mV/Pa (-30.5 dBV)Max SPL: 140 / 150 / 160 dB (0/10/20 dB pad) (0.5% THD @ 1kHz)Equivalent noise level: 9 dB(A)Dynamic range: 131 / 141 / 151 dB (0/10/20 dB Attentuation pad)Signal to Noise Ratio: 85 dBLow-cut filter: 80 / 160... Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Petite Membrane Se ElectronicsSE7 MP (paire) SEEL94094E 200 € Capsule Type 1/2“ back-electret condenser capsule Polar Pattern Cardioid Frequency range 20 Hz - 20 kHz Sensitivity 19 mV/Pa (-34.5 dBV) Max SPL 136 / 156 dBSPL (0/20 dB Attenuation pad) Equivalent noise level 16 dB(A) Dynamic range 120 / 140 dB (0/20 dB Attenuation pad) Signal to Noise Ratio 78 dB Low-cut filter... Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Petite Membrane Se ElectronicsSE7 SEEL9EA149 105 € Capsule Type 1/2“ back-electret condenser capsule Polar Pattern Cardioid Frequency range 20 Hz - 20 kHz Sensitivity 19 mV/Pa (-34.5 dBV) Max SPL 136 / 156 dBSPL (0/20 dB Attenuation pad) Equivalent noise level 16 dB(A) Dynamic range 120 / 140 dB (0/20 dB Attenuation pad) Signal to Noise Ratio 78 dB Low-cut filter... Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Petite Membrane Se ElectronicsSE8 MP (paire) SEEL8A4543 400 € Capsule Type Hand-Crafted Small-Diaphragm True Condenser Polar Pattern Cardioid Frequency range 20 Hz - 20 kHz Sensitivity 25 mV/Pa (-32 dBV) Max SPL 139 / 149 / 159 dBSPL (0/10/20 dB pad) (0.5% THD @ 1kHz) Equivalent noise level 13 dB(A) Dynamic range 126 / 136 / 146 dB (0/10/20 dB Attentuation pad) Signal to Noise... Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Petite Membrane Se ElectronicsSE8 SEELE81426 210 € Capsule Type Hand-Crafted Small-Diaphragm True Condenser Polar Pattern Cardioid Frequency range 20 Hz - 20 kHz Sensitivity 25 mV/Pa (-32 dBV) Max SPL 139 / 149 / 159 dBSPL (0/10/20 dB pad) (0.5% THD @ 1kHz) Equivalent noise level 13 dB(A) Dynamic range 126 / 136 / 146 dB (0/10/20 dB Attentuation pad) Signal to Noise... Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Grande Membrane Se ElectronicsSE2300 SEELF4C8D4 310 € Capsule Type Hand-Crafted True Condenser Polar Pattern Cardioid, Omni-directional, Figure-8 Frequency range 20 Hz - 20 kHz Sensitivity 24 mV/Pa (-32.5 dBV) Max SPL 126 / 136 / 146 dB (0/10/20 dB pad) (0.5% THD @ 1kHz) Equivalent noise level 9 dB(A) Dynamic range 117 / 127 / 137 dB (0/10/20 dB Attentuation pad) Signal to... Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Grande Membrane Se ElectronicsGemini II SEEL9A09E9 1 300 € Capsule Type Hand-Crafted True Condenser Diaphragm 35mm Gold/Mylar Directional Pattern Cardioid Frequency range 20 Hz - 20 kHz Impedance 200 Ohms Sensitivity 35.48 mV/Pa (-29 dB) Max SPL 135/145 dB (0/-10 dB pad) (0.5% THD @ 1kHz) Signal to Noise Ratio 75 dB Self Noise 19 dB(A) Pass Filter Switch 150 Hz... Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Grande Membrane Se ElectronicsX1 S Vocal Pack SEEL18AB38 170 € Capsule Type Hand-Crafted 1" True Condenser Polar Pattern Cardioid Frequency range 20 Hz - 20 kHz Sensitivity 30 mV/Pa (-30.5 dBV) Max SPL 140 / 150 / 160 dB (0/10/20 dB pad) (0.5% THD @ 1kHz) Equivalent noise level 9 dB(A) Dynamic... Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Grande Membrane Se ElectronicsSE2200 SEEL4F614B 230 € Capsule Type: Hand-Crafted 1" True Condenser Polar Pattern: Cardioid Frequency range: 20 Hz - 20 kHz Sensitivity: 23.7 mV/Pa (-32.5 dBV) Max SPL: 125 / 135 / 145 dB (0/10/20 dB pad) (0.5% THD @ 1kHz) Equivalent noise level: 12 dB(A) Dynamic range: 113 / 123 / 133 dB (0/10/20 dB Attentuation pad) Signal to Noise Ratio: 82 dB Low-cut filter: 80 / 160 Hz, 6... Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Grande Membrane Se ElectronicsX1 A SEELA47575 95 € Capsule Type: 2/3" Permanently-Biased Condenser Directional Pattern: Cardioid Frequency range: 20 Hz - 20 kHz Impedance: <50 Ohms Sensitivity: 20 mV/Pa (-34 dB) Max SPL: 130 / 150 dB (0 / 20 dB pad, (0.5% THD @ 1kHz) Signal to Noise... Ajouter au panier
Hors Stock Appeler pour vérifier Micros à Main Se ElectronicsV3 SEELC81092 70 € Capsule DynamicVoice Coil CopperMagnet NeodymiumDirectional Pattern CardioidFrequency range 50 Hz - 16 kHzImpedance 600 OhmsSensitivity 2.5 mV/Pa (-52 dB)Connectivity 3-pin male XLRDiameter 52 mm (2.05 in.) x Length 181 mm (7.13 in.)Weight 295 g / 10.4 oz Ajouter au panier
Hors Stock Appeler pour vérifier Accessoires Se ElectronicsRF PRO B2 SEEL64C04B 55 € Ajouter au panier
Hors Stock Appeler pour vérifier Accessoires Se ElectronicsDual Pro Pop SEELEC644E 40 € Ajouter au panier
Hors Stock Appeler pour vérifier Accessoires Se ElectronicsIsolation pack SEELA12AF5 50 € Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Grande Membrane Se ElectronicsX1 SStudio Bundle SEELEC235R 240 € Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Petite Membrane Se ElectronicsRN17 ST (paire) SEELB84975 1 620 € Ajouter au panier
Hors Stock Appeler pour vérifier Micros Condensateur à Petite Membrane Se ElectronicsRN17 Cardioid Cut Caps SEEL4C2AAC 390 € Ajouter au panier